The operating parameters of the air heat exchanger used at the stage of cooling the butadiene fraction in the production of methyl tert-butyl ether are analyzed. The insufficient efficiency of its operation in the summer period has been revealed. The solution is to make changes to the design of the heat exchanger. Installing an air heat exchanger with a larger heat transfer surface is not economically feasible
air heat exchanger, constructive, heat transfer, efficiency
1. Lebedev N.N. Himiya i tehnologiya osnovnogo organicheskogo i neftehimicheskogo sinteza: Uchebnik dlya vuzov. M.: Himiya, 1988. 592 s.
2. Ispol'zovanie spirtov kak dobavok k neftyanym toplivam. Al'ternativnye topliva, energetika. Analiticheskiy portal himicheskoy promyshlennosti: http://www.Newchemistry.ru (data obrascheniya 29.04.20).
3. Ul'yanov B.A., Badenikov V.Ya., Likuchev V.G. Processy i apparaty himicheskoy tehnologii M.: Himiya, 2006. 557 s.
4. Scherbin S.A. Osnovy teorii teploobmena i teploobmennye apparaty. Angarsk: AGTA, 2014. 159 s.
5. Apparat vozdushnogo ohlazhdeniya. Pasport. Voronezh: OOO «Gribanovskiy mashinostroitel'nyy zavod», 2010. 222
6. Sidyagin A.A. Raschet i proektirovanie apparatov vozdushnogo ohlazhdeniya. N.Novgorod: Nizhegorod. gos. tehn. un-t im. R.E. Alekseeva, 2009. 150 s.
7. Klimat: Angarsk - klimaticheskiy grafik, grafik temperatury, klimaticheskaya tablica. https://ru.climate-data.org/aziya/rossiiskaya-federaciya/irkutskayaoblast'/angarsk-1827/ (data obrascheniya 29.04.20).