The arcticle describes results of determination of the induced traction network 25 kV on the pipeline with a diameter of 250 millimeters. This shows that due to the electromagnetic influence on the pipeline dangerous voltage can be induced. With a closing distance of 100 meters, the amount of voltage imposed on the pipeline at individual points of a pipeline earthed from both sides can exceed a voltage of 110 V. This circumstance requires special attention to protect the personal of the service pipeline.