ELECTROMAGNETIC INFLUENCE OF RAILWAYS ON PIPELINES GROUND FLOORING
Abstract and keywords
Abstract (English):
The arcticle describes results of determination of the induced traction network 25 kV on the pipeline with a diameter of 250 millimeters. This shows that due to the electromagnetic influence on the pipeline dangerous voltage can be induced. With a closing distance of 100 meters, the amount of voltage imposed on the pipeline at individual points of a pipeline earthed from both sides can exceed a voltage of 110 V. This circumstance requires special attention to protect the personal of the service pipeline.

Keywords:
power supply systems of railways, pipelines, induced voltages, modeling.
Text
Publication text (PDF): Read Download
References

1. Ratner M.P. Induktivnoe vliyanie elektrificirovannyh zheleznyh dorog na elektricheskie seti i truboprovody. M.: Transport, 1966. 164 s.

2. Konovalov Yu.V., Abramovich B.N. , Ustinov D.A. Elektromehanicheskie kompleksy s sinhronnymi dvigatelyami. Modelirovanie, vybor i realizaciya energoeffektivnyh rezhimov. LAP LAMBERT Academic Publishing GmbH & Co. KG, 2013. 121 s.

3. Zakaryukin V.P., Kryukov A. V., Ivanova A.P. Komp'yuternoe modelirovanie elektromagnitnogo vliyaniya tyagovyh setey na truboprovody // Vestnik IrGTU. T. 21. № 5. 2017.