STABILITY OF THE METAL FRAME ELEMENTS WHEN WORKING IN CRAMPED CONDITIONS
Abstract and keywords
Abstract (English):
The static operation of the building frame elements formed from thin-walled open profiles located in a monolithic foam concrete array is considered. This arrangement increases the overall stability and fire resistance of the floor beams.

Keywords:
metal frame, thin-walled profile, foam concrete
Text
Publication text (PDF): Read Download
References

1. Konstrukcii grazhdanskih zdaniy / pod red. M.S. Tupoleva - M.: Arhitektura-S, 2007. 240 s.

2. STO 047-2005. Perekrytiya stalezhelezobetonnye s monolitnoy plitoy po stal'nomu profilirovannomu nastilu. - M.: CNIIPSK im. Mel'nikova, 2005. 66 s.

3. Tusnin A.R. Oblegchennye perekrytiya mnogoetazhnyh zdaniy so stal'nym karkasom // Promyshlennoe i grazhdanskoe stroitel'stvo. 2016. № 10. S. 99-103.

4. Savenkov A.I., Gorbach P.S., Scherbin A.S. Neavtoklavnyy penobeton. Faktory kachestva. Monografiya. - Angarsk: Izdatel'stvo Angarskoy gosudarstvennoy tehnicheskoy akademii, 2013. - 104 s